Hunter-fan 47550 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Schalttafel Hunter-fan 47550 herunter. Hunter Fan 47550 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - AUTO SAVER 550

OwnerÕs Manual Model 47550SINCE 1 8 8 6®AUTO SAVER 5505:72223

Seite 2 - Ask Your Local Retailer for

10-11INSTALLATIONThis thermostat includes two #8 slotted screws and two wallanchors for mounting. To install your thermostat, you should havethe follo

Seite 3 - Introduction

Each wire coming from the wall to the existing thermostat isconnected to a terminal point on that thermostat. Each of theseterminal points is usuall

Seite 4 - Table of Contents

Remove the wallplate from your thermostat by pressing therelease tab on the bottom of the thermostat. (See Figure 2.) Position wallplate on wall and

Seite 5 - Table of Contents (continued)

Match and connect the labeled wires to the appropriatecoded terminal screws on the mounting plate. (SeeFigure 4, 5.) Ignore any wires which may be p

Seite 6

In order for this Hunter thermostat to control your system, thesystem type must be specified by selector switches on the printedcircuit board inside t

Seite 7

Switch SettingSwitch Function Alternate StandardSW 5 F° / C° Celsius FahrenheitSW 6 12 Hr. / 24 Hr. 24 Hour 12 HourSW 7 Span +2°F / –1°F +1°F / –1°FSW

Seite 8 - Features

16-17PROGRAMMINGRemove the mylar label covering the LCD display window before operating thermostat.Setting Time and DayHOURMINDAYRETURNEXAMPLE: Set th

Seite 9

Studies conducted by the Department of Energy estimate thatsetting your thermostat back 10°F (6°C) for two 8-hour periodsduring winter can reduce your

Seite 10 - INSTALLATION

18-19PROGRAMMINGPersonal Program ScheduleDay Program 1 Program 2 Program 3 Program 4Mon. Time Time Time TimeTemp Temp Temp TempTues. Time Time Time Ti

Seite 11 - Wire Labeling

Your thermostat can be programmed for weekdays andweekends, or have unique programs for all 7 days. UseWeekday/Weekend Programming below or 7-day Pr

Seite 12

Ask Your Local Retailer forOther Quality Products from HunterTo locate your nearest Hunter Dealer, call 1-800-4HUNTER,or visit The Hunter Fan Company

Seite 13 - FIGURE 5

20-21PROGRAMMINGWeekday/Weekend Programming (cont.)Step 3Step 5 Press to change to weekend programs. Repeat Steps 3 and 4 to complete the weekend pr

Seite 14

Step 2 Press to enter program mode, display shows weekday programs. Press 2 times to reach the Monday program.PROGStep 3PROGDAYStep 5 Press to chan

Seite 15 - Feature Selector Summary:

You may want to review the programs to confirm that the settings are compatible with your lifestyle.22-23PROGRAMMINGReviewing ProgramsWeekdayPrograms

Seite 16 - PROGRAMMING

DailyPrograms Press to display M – F programs.NOTE: Time and Temperature display will be blank when at least oneweekday program is different. Press

Seite 17 - AUTO COOL HEAT

The System Selector switch on the front of the thermostat determines the operating mode of the thermostat.You may select COOL, OFF, HEAT, AUTO. In ord

Seite 18

To end the Temporary Manual Override:NOTE: The Auto Season Changeover feature will not operate while the thermostat is in Temporary ManualOverride. Re

Seite 19 - -- -- --

When the System Selector is in AUTO position, the thermostatwill automatically change between Heating and Cooling systems,depending on your program. W

Seite 20

Press to exit Home Today mode before the schedule ending time.“HOME” is no longer displayed on the LCD screen, and thethermostat returns to the curr

Seite 21 - 7-Day Programming

72.7I.70.28-29OPERATIONEnergy MonitorENERGYENERGY Press and hold for 3 seconds to reset the Energy Monitor’s counters.The display will blink, and all

Seite 22

Your thermostat also keeps a record of the number of hours your filter has been in use. To maximize your system’s performance and energyefficiency, ch

Seite 23

IntroductionModel Information:Model Number ____________________________________Serial Number _____________________________________Date Purchased______

Seite 24 - OPERATION

72.7I.70.30-31OPERATIONAuto RecoveryHunter’s Auto Recovery feature meets the ENERGYSTAR®guidelinesfor energy efficiency by allowing the heating or coo

Seite 25 - SET TEMP

Backlighting (INDIGLO®night-light) Press the Light Bar on the left side of the thermostat to illuminate thedisplay. The display will remain illumina

Seite 26

When the batteries become too weak for normal operation, thethermostat enters the second stage low battery warning whichshuts down the thermostat. In

Seite 27

If the thermostat is unable to control your system due to anunexpected battery problem, the thermostat will enter ErrorMode. In this condition, the th

Seite 28

34-35TROUBLESHOOTINGProblem SolutionSCRAMBLED OR DOUBLE DISPLAY(numbers over numbers)NO DISPLAYENTIRE DISPLAY DIMSPROGRAM DOES NOT CHANGE AT YOUR DESI

Seite 29

Solution (cont.)ERRATIC DISPLAYIF UNIT CONTINUES TO OPERATE IN THE OFF POSITIONTHERMOSTAT PERMANENTLY READS “HI,” “LO,” OR “ERR-” AFTER PRESSING RESET

Seite 30

36-37WIRING DIAGRAMS5-wire Heat/Cool SystemX - No ConnectionTHERMOSTATGWYRHRCHeat Relayor ValveHeat24V SupplyFanRelayCoolContactorCool24V SupplyTHERMO

Seite 31

Single-stage Heat PumpTHERMOSTATGWYO/BRHRCHeat Pump24V SupplyFanRelayCompressorContactorReversingValveJumperX - No ConnectionO/B2-wire Heat OnlyTHERMO

Seite 32 - SAFETY FEATURES

3-wire Cool Only3-wire Heat OnlyTHERMOSTATWRHRCHeat Relayor ValveHeat24V SupplyFanRelayTHERMOSTATGWYRHRCCoolContactorFanRelayCool24V SupplyG YO/BO/B38

Seite 33 - Auto Cut-Off

Table of ContentsRead This Before Installing Thermostat 6Features 8What You Need 10Remove Old Thermostat 10Wire Labeling 11Mount Wallplate and Thermos

Seite 34 - TROUBLESHOOTING

OPERATIONS (continued)SAFETY FEATURESTROUBLESHOOTINGWIRING DIAGRAMSTemporary Manual Override 24Permanent Manual (Vacation) Override 25Auto Season Chan

Seite 35 - Problem (cont.)

IMPORTANT1Read the entire installation section of this Owner’sManual thoroughly before you begin to install oroperate your Hunter Thermostat.REMOVE TH

Seite 36 - WIRING DIAGRAMS

Read This Before Installing Thermostat (continued)POWER FAILURE7Whenever the main power is interrupted or fails, thebattery power retains the programs

Seite 37 - 2-wire Heat Only

FeaturesHOME TODAY: Overrides energy-saving program temperatures whileyou are at home for the day.ENERGY: Measures anddisplays heating and cooling sys

Seite 38

Provides permanenttemperature setting byoverriding storedprograms. It also returnsthe thermostat to currentprogram control frommanual override or Home

Kommentare zu diesen Handbüchern

Keine Kommentare